# For a description of the syntax of this configuration file,
# see the file kconfig-language.txt in the NuttX tools repository.
#

menuconfig EXAMPLES_FOC
	tristate "FOC motor controller example"
	depends on MOTOR_FOC
	depends on INDUSTRY_FOC
	---help---
		Enable the FOC motor controller example.
		At the moment, this example implements a simple open-loop velocity controller.

if EXAMPLES_FOC

config EXAMPLES_FOC_DEVPATH
	string "FOC device path prefix"
	default "/dev/foc"
	---help---
		The default path to the FOC device without the device minor number.
		Default: /dev/foc

config EXAMPLES_FOC_FLOAT_INST
	int "FOC float instances"
	depends on INDUSTRY_FOC_FLOAT
	default 0

config EXAMPLES_FOC_FIXED16_INST
	int "FOC fixed16 instances"
	depends on INDUSTRY_FOC_FIXED16
	default 0

config EXAMPLES_FOC_CONTROL_PRIO
	int "FOC control thread priority"
	default 255

config EXAMPLES_FOC_CONTROL_STACKSIZE
	int "FOC control thread stack size"
	default 4096

config EXAMPLES_FOC_VERBOSE
	int "Enable verbose print for app"
	default 1
	range 0 2

config EXAMPLES_FOC_PWM_FREQ
	int "FOC PWM frequency"
	default 10000
	---help---
		Select the FOC PWM switching frequency

config EXAMPLES_FOC_NOTIFIER_FREQ
	int "FOC notifier frequency"
	default EXAMPLES_FOC_PWM_FREQ
	---help---
		Select the FOC notifier frequency

config EXAMPLES_FOC_IPHASE_ADC
	int "FOC phase current scale [x100000]"
	default 0
	---help---
		This parameter is used to get real currents from ADC RAW values

config EXAMPLES_FOC_STATE_PRINT_FREQ
	int "FOC example data printer frequency"
	default 0
	depends on INDUSTRY_FOC_HANDLER_PRINT
	---help---
		Set 0 to disable FOC data print

config EXAMPLES_FOC_STATE_USE_MODEL_PMSM
	bool "FOC uses PMSM model"
	depends on INDUSTRY_FOC_MODEL_PMSM
	default n
	---help---
		Use PMSM model instead of real hardware

menu "FOC user input"

config EXAMPLES_FOC_HAVE_ADC
	bool
	default n

choice
	prompt "FOC VBUS source"
	default EXAMPLES_FOC_VBUS_CONST

config EXAMPLES_FOC_VBUS_CONST
	bool "Use hardcoded constant VBUS value"

config EXAMPLES_FOC_VBUS_ADC
	bool "Use VBUS provided by ADC interface"
	depends on ADC
	select EXAMPLES_FOC_HAVE_ADC

endchoice # FOC VBUS interface

if EXAMPLES_FOC_VBUS_CONST

config EXAMPLES_FOC_VBUS_CONST_VALUE
	int "FOC VBUS constant value"
	default 12000

endif # EXAMPLES_FOC_VBUS_CONST

if EXAMPLES_FOC_HAVE_ADC

config EXAMPLES_FOC_ADC_DEVPATH
	string "FOC ADC interface path"
	default "/dev/adc0"

config EXAMPLES_FOC_ADC_VREF
	int "FOC ADC reference votlage [x1000]"
	default 0

config EXAMPLES_FOC_ADC_MAX
	int "FOC ADC aux maximum sample value"
	default 0

endif # EXAMPLES_FOC_HAVE_ADC

if EXAMPLES_FOC_VBUS_ADC

config EXAMPLES_FOC_VBUS_SCALE
	int "FOC VBUS SCALE scale [x1000]"
	default 0

endif # EXAMPLES_FOC_VBUS_ADC

choice
	prompt "FOC velocity source"
	default EXAMPLES_FOC_VEL_CONST

config EXAMPLES_FOC_VEL_CONST
	bool "Use hardcoded constant velocity value"

config EXAMPLES_FOC_VEL_ADC
	bool "Use ADC to control velocity"
	select EXAMPLES_FOC_HAVE_ADC

endchoice # FOC velocity interface

if EXAMPLES_FOC_VEL_CONST

config EXAMPLES_FOC_VEL_CONST_VALUE
	int "FOC hardoced velocity value"
	default 100000

endif # EXAMPLES_FOC_VEL_CONST

if EXAMPLES_FOC_VEL_ADC

config EXAMPLES_FOC_VEL_ADC_MAX
	int "FOC maximum velocity from ADC [x1000]"
	default 100000

endif # EXAMPLES_FOC_VEL_ADC

config EXAMPLES_FOC_TIME_DEFAULT
	int "FOC run time default (sec)"
	default 10

config EXAMPLES_FOC_STATE_INIT
	int "FOC motor controller state init"
	default 1
	range 1 4
	---help---
		1 - motor FREE (no current)
		2 - motor STOP (active break)
		3 - motor moves in CW direction
		4 - motor moves in CCW direction

config EXAMPLES_FOC_HAVE_BUTTON
	bool "FOC button support"
	default n
	---help---
		The button is used to change the motor controller state

if EXAMPLES_FOC_HAVE_BUTTON

config EXAMPLES_FOC_BUTTON_DEVPATH
	string "FOC button device path"
	default "/dev/buttons"
	depends on INPUT_BUTTONS

endif

endmenu # FOC user input

menu "FOC controller parameters"

config EXAMPLES_FOC_OPMODE
	int "FOC operation mode"
	default 2
	range 1 3
	---help---
		1 - IDLE mode
		2 - voltage open-loop velocity controller (default)
		3 - current open-loop velocity controller

config EXAMPLES_FOC_OPENLOOP_Q
	int "FOC open-loop Vq/Iq setting [x1000]"
	default 200

config EXAMPLES_FOC_IDQ_KP
	int "FOC PI controller Kp gain [x1000]"
	default 0
	---help---
		It is set to 0 by default and must be properly configured by the user!
		The vaule of Kp and Ki depends on the controlled motor parameters.
		For more instructions see README.md for this example.

config EXAMPLES_FOC_IDQ_KI
	int "FOC PI controller Ki gain [x1000]"
	default 0
	---help---
		It is set to 0 by default and must be properly configured by the user!
		The vaule of Kp and Ki depends on the controlled motor parameters.
		For more instructions see README.md for this example.

config EXAMPLES_FOC_RAMP_THR
	int "FOC velocity ramp threshold [x1000]"
	default 0

config EXAMPLES_FOC_RAMP_ACC
	int "FOC velocity ramp acc [x1000]"
	default 0

config EXAMPLES_FOC_RAMP_DEC
	int "FOC velocity ramp acc [x1000]"
	default 0

endmenu # FOC controller parameters

endif # EXAMPLES_FOC